Conductor Technology:
1

Winding Window Space (Shared Window)

2

Conductor Specification & Insulation

3

Electrical & Thermal Parameters

Conductor Spec 1 × ⌀1.00 mm Enamel OD: ⌀1.14 mm
Wire Diameter ⌀1.14 mm Bare copper: ⌀1.00 mm
AC Loss Factor F_R (AC/DC) 10.79× Skin depth δ: 0.240 mm
Copper Loss P_Cu 156.12 W R_AC = 481.8 mΩ (R_DC = 44.6 mΩ)
Conductor Cross-Section & Current Density Adaptive Cross-Section
Window Build Utilization PASS
23.2 % (≤ 80% Safe)
0.0 Warn: 80.0 Max: 100.0

Ratio of total winding build thickness W_build to usable window width W_usable.

AC Proximity Factor (F_R) FAIL
10.8 × (≤ 1.6 Optimal)
1.0 Warn: 1.6 Max: 2.5

AC resistance multiplier due to proximity and skin effect (Dowell).

Current Density (J) FAIL
22.9 A/mm² (Target: 6 A/mm²)
0.0 Warn: 6.9 Max: 8.1

Actual RMS current density in bare copper cross-section.

🩺

Winding Health & Diagnostics

1 Notice
TIP

Alternative Conductor Recommendation

On this shared core window, switching to Copper Foil yields a 90% reduction in AC copper loss (15.35 W vs. 156.12 W).

Recommendation: Switch to the Copper Foil tab to evaluate detailed winding parameters.
📊

Compare 5 Conductor Technologies on Shared Window

Shared Window Evaluation · Dowell 1D Loss Comparison
Conductor TechnologyProposed SpecR_DC (mΩ)F_R (×)R_AC (mΩ)Loss P_Cu (W)Cu Fill (Ku)Build Util (%)Window FitAction
Litz Wire
100/0.100 (20 × 5)45.81.35×61.719.98 W7.2%29%✓ PASS
Solid / Multifilar Wire Active
1 × ⌀1.00 mm44.610.79×481.8156.12 W7.2%23%✓ PASSActive
Flat / Edgewise Wire
1.53 × 0.51 mm (Edgewise)43.12.80×120.839.13 W7.2%16%✓ PASS
Copper Foil
23.4 mm × 34 µm46.51.02×47.415.35 W7.2%32%✓ PASS
Planar PCB Coil
12-Layer Stackup, 3 oz (7.5 mm trace)60.41.20×72.123.37 W7.2%95%⚠ TIGHT

Related Tools