1
Winding Window Space (Shared Window)
2
Conductor Specification & Insulation
3
Electrical & Thermal Parameters
Conductor Spec 3.00 × 0.80 mm (Edgewise) Cu area: 2.40 mm²
WINDING BUILD & FILL 3.10 mm (1 Layers) Layer fill η: 31.0% | +50 µm Mylar
AC Loss Factor F_R (AC/DC) 5.58× Skin depth δ: 0.240 mm
Copper Loss P_Cu 27.41 W R_AC = 84.6 mΩ (R_DC = 15.2 mΩ)
Conductor Cross-Section & Current Density Adaptive Cross-Section
Window Build Utilization PASS
31.0 % (≤ 80% Safe)
0.0 Warn: 80.0 Max: 100.0
Ratio of total winding build thickness W_build to usable window width W_usable.
AC Proximity Factor (F_R) FAIL
5.6 × (≤ 1.6 Optimal)
1.0 Warn: 1.6 Max: 2.5
AC resistance multiplier due to proximity and skin effect (Dowell).
Current Density (J) WARNING
7.5 A/mm² (Target: 6 A/mm²)
0.0 Warn: 6.9 Max: 8.1
Actual RMS current density in bare copper cross-section.
🩺
1
NoticeWinding Health & Diagnostics
TIP
Alternative Conductor Recommendation
On this shared core window, switching to Planar PCB Coil yields a 62% reduction in AC copper loss (9.45 W vs. 24.60 W).
Recommendation: Switch to the Planar PCB Coil tab to evaluate detailed winding parameters.
📊
Shared Window Evaluation · Dowell 1D Loss ComparisonCompare 5 Conductor Technologies on Shared Window
| Conductor Technology | Proposed Spec | R_DC (mΩ) | F_R (×) | R_AC (mΩ) | Loss P_Cu (W) | Cu Fill (Ku) | Build Util (%) | Window Fit | Action |
|---|---|---|---|---|---|---|---|---|---|
Litz Wire | 304/0.100 (19 × 4 × 4) | 18.3 | 3.37× | 61.5 | 19.93 W | 22.2% | 75% | ✓ PASS | |
Solid / Multifilar Wire | 2filar × ⌀1.24 mm | 16.0 | 27.68× | 443.5 | 143.69 W | 22.2% | 43% | ✓ PASS | |
Flat / Edgewise Wire Active | 2.68 × 0.89 mm (Edgewise) | 14.9 | 5.08× | 75.9 | 24.60 W | 22.2% | 28% | ✓ PASS | Active |
Copper Foil | 23.4 mm × 103 µm | 16.4 | 2.74× | 44.9 | 14.54 W | 22.2% | 48% | ✓ PASS | |
Planar PCB Coil | 12-Layer Stackup, 3 oz (22.9 mm trace) | 19.8 | 1.48× | 29.2 | 9.45 W | 22.2% | 95% | ⚠ TIGHT |