Conductor Technology:
1

Winding Window Space (Shared Window)

2

Conductor Specification & Insulation

3

Electrical & Thermal Parameters

Conductor Spec 3.00 × 0.80 mm (Edgewise) Cu area: 2.40 mm²
WINDING BUILD & FILL 3.10 mm (1 Layers) Layer fill η: 31.0% | +50 µm Mylar
AC Loss Factor F_R (AC/DC) 5.58× Skin depth δ: 0.240 mm
Copper Loss P_Cu 27.41 W R_AC = 84.6 mΩ (R_DC = 15.2 mΩ)
Conductor Cross-Section & Current Density Adaptive Cross-Section
Window Build Utilization PASS
31.0 % (≤ 80% Safe)
0.0 Warn: 80.0 Max: 100.0

Ratio of total winding build thickness W_build to usable window width W_usable.

AC Proximity Factor (F_R) FAIL
5.6 × (≤ 1.6 Optimal)
1.0 Warn: 1.6 Max: 2.5

AC resistance multiplier due to proximity and skin effect (Dowell).

Current Density (J) WARNING
7.5 A/mm² (Target: 6 A/mm²)
0.0 Warn: 6.9 Max: 8.1

Actual RMS current density in bare copper cross-section.

🩺

Winding Health & Diagnostics

1 Notice
TIP

Alternative Conductor Recommendation

On this shared core window, switching to Planar PCB Coil yields a 62% reduction in AC copper loss (9.45 W vs. 24.60 W).

Recommendation: Switch to the Planar PCB Coil tab to evaluate detailed winding parameters.
📊

Compare 5 Conductor Technologies on Shared Window

Shared Window Evaluation · Dowell 1D Loss Comparison
Conductor TechnologyProposed SpecR_DC (mΩ)F_R (×)R_AC (mΩ)Loss P_Cu (W)Cu Fill (Ku)Build Util (%)Window FitAction
Litz Wire
304/0.100 (19 × 4 × 4)18.33.37×61.519.93 W22.2%75%✓ PASS
Solid / Multifilar Wire
2filar × ⌀1.24 mm16.027.68×443.5143.69 W22.2%43%✓ PASS
Flat / Edgewise Wire Active
2.68 × 0.89 mm (Edgewise)14.95.08×75.924.60 W22.2%28%✓ PASSActive
Copper Foil
23.4 mm × 103 µm16.42.74×44.914.54 W22.2%48%✓ PASS
Planar PCB Coil
12-Layer Stackup, 3 oz (22.9 mm trace)19.81.48×29.29.45 W22.2%95%⚠ TIGHT