1
Winding Window Space (Shared Window)
2
Conductor Specification & Insulation
3
Electrical & Thermal Parameters
Foil Spec 22.0 mm × 200 µm Cu area/turn: 4.40 mm²
WINDING BUILD & FILL 5.95 mm (24 Layers) Layer fill η: 59.5% | +50 µm Mylar
AC Loss Factor F_R (AC/DC) 22.94× Skin depth δ: 0.240 mm
Copper Loss P_Cu 69.69 W R_AC = 215.1 mΩ (R_DC = 9.4 mΩ)
Conductor Cross-Section & Current Density Adaptive Cross-Section
Window Build Utilization PASS
59.5 % (≤ 80% Safe)
0.0 Warn: 80.0 Max: 100.0
Ratio of total winding build thickness W_build to usable window width W_usable.
AC Proximity Factor (F_R) FAIL
22.9 × (≤ 1.6 Optimal)
1.0 Warn: 1.6 Max: 2.5
AC resistance multiplier due to proximity and skin effect (Dowell).
Current Density (J) PASS
4.1 A/mm² (Target: 6 A/mm²)
0.0 Warn: 6.9 Max: 8.1
Actual RMS current density in bare copper cross-section.
🩺
1
NoticeWinding Health & Diagnostics
TIP
Alternative Conductor Recommendation
On this shared core window, switching to Planar PCB Coil yields a 92% reduction in AC copper loss (5.16 W vs. 64.39 W).
Recommendation: Switch to the Planar PCB Coil tab to evaluate detailed winding parameters.
📊
Shared Window Evaluation · Dowell 1D Loss ComparisonCompare 5 Conductor Technologies on Shared Window
| Conductor Technology | Proposed Spec | R_DC (mΩ) | F_R (×) | R_AC (mΩ) | Loss P_Cu (W) | Cu Fill (Ku) | Build Util (%) | Window Fit | Action |
|---|---|---|---|---|---|---|---|---|---|
Litz Wire | 555/0.100 (37 × 3 × 5) | 12.3 | 8.68× | 106.3 | 34.46 W | 40.6% | 133% | ✕ OVERFLOW | |
Solid / Multifilar Wire | 2filar × ⌀1.67 mm | 10.1 | 59.89× | 603.4 | 195.51 W | 40.6% | 77% | ✓ PASS | |
Flat / Edgewise Wire | 3.63 × 1.21 mm (Edgewise) | 10.0 | 20.50× | 204.7 | 66.34 W | 40.6% | 75% | ✓ PASS | |
Copper Foil Active | 23.4 mm × 188 µm | 9.7 | 20.42× | 198.7 | 64.39 W | 40.6% | 69% | ✓ PASS | Active |
Planar PCB Coil | 12-Layer Stackup, 3 oz (41.9 mm trace) | 10.8 | 1.48× | 15.9 | 5.16 W | 40.6% | 95% | ⚠ TIGHT |