Conductor Technology:
1

Winding Window Space (Shared Window)

2

Conductor Specification & Insulation

3

Electrical & Thermal Parameters

Foil Spec 22.0 mm × 200 µm Cu area/turn: 4.40 mm²
WINDING BUILD & FILL 5.95 mm (24 Layers) Layer fill η: 59.5% | +50 µm Mylar
AC Loss Factor F_R (AC/DC) 22.94× Skin depth δ: 0.240 mm
Copper Loss P_Cu 69.69 W R_AC = 215.1 mΩ (R_DC = 9.4 mΩ)
Conductor Cross-Section & Current Density Adaptive Cross-Section
Window Build Utilization PASS
59.5 % (≤ 80% Safe)
0.0 Warn: 80.0 Max: 100.0

Ratio of total winding build thickness W_build to usable window width W_usable.

AC Proximity Factor (F_R) FAIL
22.9 × (≤ 1.6 Optimal)
1.0 Warn: 1.6 Max: 2.5

AC resistance multiplier due to proximity and skin effect (Dowell).

Current Density (J) PASS
4.1 A/mm² (Target: 6 A/mm²)
0.0 Warn: 6.9 Max: 8.1

Actual RMS current density in bare copper cross-section.

🩺

Winding Health & Diagnostics

1 Notice
TIP

Alternative Conductor Recommendation

On this shared core window, switching to Planar PCB Coil yields a 92% reduction in AC copper loss (5.16 W vs. 64.39 W).

Recommendation: Switch to the Planar PCB Coil tab to evaluate detailed winding parameters.
📊

Compare 5 Conductor Technologies on Shared Window

Shared Window Evaluation · Dowell 1D Loss Comparison
Conductor TechnologyProposed SpecR_DC (mΩ)F_R (×)R_AC (mΩ)Loss P_Cu (W)Cu Fill (Ku)Build Util (%)Window FitAction
Litz Wire
555/0.100 (37 × 3 × 5)12.38.68×106.334.46 W40.6%133%✕ OVERFLOW
Solid / Multifilar Wire
2filar × ⌀1.67 mm10.159.89×603.4195.51 W40.6%77%✓ PASS
Flat / Edgewise Wire
3.63 × 1.21 mm (Edgewise)10.020.50×204.766.34 W40.6%75%✓ PASS
Copper Foil Active
23.4 mm × 188 µm9.720.42×198.764.39 W40.6%69%✓ PASSActive
Planar PCB Coil
12-Layer Stackup, 3 oz (41.9 mm trace)10.81.48×15.95.16 W40.6%95%⚠ TIGHT

Related Tools